iQBus connects your LIS, analyzers and ordering EHRs, translating HL7 v2.x orders and ORU^R01 results into FHIR R4 / R5, with every message tracked end to end. It runs entirely inside your Azure tenant, so PHI stays inside your compliance boundary.

Not a laboratory? See the general HL7 / FHIR integration platform.

Start license-free on Azure Marketplace you pay only your own Azure
  • Built by Microsoft V-TSP consultants
  • iQBus supports SOC 2 and HIPAA
  • Microsoft Solutions Partner
Result transformation

An ORU^R01 → FHIR Observation. Hover either side to trace the mapping.

A glucose result leaves your LIS as an HL7 v2.5.1 ORU^R01 and arrives at the ordering EHR as a FHIR R4 Observation, mapped in XSLT 3.0. Hover any HL7 segment to highlight its mapped FHIR property, in either direction.

HL7 v2.5.1 · ORU^R01From: LIS / Roche cobas analyzer · via SFTP, file share or API
FHIR R4 · ObservationTo: ordering EHR · FHIR REST API
MSH|^~\&|LIS|REFLAB|EHR|HOSP|20260514143211||ORU^R01|L260514-0421|P|2.5.1
PID|||MRN12345^^^EPIC^MRN||DOE^JOHN^M||19751023|M
OBR|1|||CBC^Complete Blood Count
OBX|1|NM|2345-7^Glucose^LN||92|mg/dL|70-100|N|||F
Field map · XSLT 3.0 MSH-10id PID-3subject.reference OBX-3code.coding OBX-5valueQuantity.value OBX-6valueQuantity.unit OBX-7referenceRange OBX-8interpretation OBX-11status
{
  "resourceType": "Observation",
  "id": "obs-L260514-0421",
  "status": "final",
  "category": [{
    "coding": [{ "code": "laboratory" }]
  }],
  "code": {
    "coding": [{
      "system": "http://loinc.org",
      "code": "2345-7",
      "display": "Glucose"
    }]
  },
  "subject": { "reference": "Patient/MRN12345" },
  "valueQuantity": {
    "value": 92,
    "unit": "mg/dL",
    "system": "http://unitsofmeasure.org"
  },
  "referenceRange": [{
    "low":  { "value": 70 },
    "high": { "value": 100 }
  }],
  "interpretation": [{
    "coding": [{ "code": "N" }]
  }]
}
Hover or tap any HL7 segment (e.g. OBX, PID, MRN12345) and its mapped FHIR property highlights on the right. The mapping is bidirectional: hover the right side to find the source HL7 segment.

Who it is for

The people a lab result passes through

From the draw station to the ordering physician, every hop is a message.

A phlebotomist labels a blood sample tube with a barcode at a draw station as a patient rolls down his sleeveCollectionThe order follows the tubeOrders from the ordering EHR arrive as HL7 messages, so the lab knows what is coming before the sample does.
A laboratory scientist loads a rack of sample tubes into an automated analyzerLaboratoryFrom the analyzer to every system that needs itResults move from instruments through your LIS to the EHR and beyond, and each message is tracked end to end.
A pathologist reviews results on a monitor beside a microscope while a lab manager discusses a caseLab leadershipEvery result traceable at inspectionWhen CAP or CLIA inspectors ask where a result went, the flow tracking dashboard shows every message and every hop.Learn more
Lab operations console · preview

Every accession, every result, observable end to end.

The structure your laboratory operations team works with in the tracking dashboard, rendered into the page with sample data so you can feel how it behaves. Hover any row to surface the message ID; the status tells you where each message stands in the pipeline.

Inbound clinical traffic · last 60 seconds · 6 of 2,419 shown

Sample data
TimeSource · SystemTypeAccession · PatientStatus
14:32:11Roche cobas · LISORU^R01L260514-0421 · MRN12345FHIR R4msg00421
14:31:58Epic Beaker · orderORM^O01L260514-0420 · MRN98701Routedmsg00420
14:31:45Sysmex XN · LISORU^R01L260514-0419 · MRN24508Transformingmsg00419
14:31:28Abbott Architect · LISORU^R01L260514-0418 · MRN77104FHIR R4msg00418
14:31:09Illumina NovaSeq · NGSOUL^R22L260514-0417 · QC pendingQC reviewmsg00417
14:30:47Oracle Cerner · orderORM^O01L260514-0416 · MRN31200Routedmsg00416
Message taxonomy

Every HL7 event your lab moves, mapped to the FHIR your EHR consumes.

One mapping engine, XSLT 3.0 over XML and JSON. A C# pipeline component parses each inbound HL7 v2.x event, and your maps shape it into US Core FHIR resources.

HL7 v2.x in

ORU^R01 resultOML^O21 lab orderORM^O01 orderADT^A01 admit

+ 8 more event types

iQBus mapping engine parse · map · route
XSLT 3.0US CoreLOINCSNOMED CT

FHIR R4 / R5 out

DiagnosticReportObservationSpecimenServiceRequest

+ 8 US Core resources

LOINC codes carried through every OBX · RxNorm, ICD-10-CM and UCUM normalization written into your maps · IHE LAB-TF (LCC, LBL, LAW) and PIX/PDQ/XDS built for your engagement.

View the full event & resource mapHide the full map

HL7 v2.x lab & clinical events

  • ORM^O01Order
  • OML^O21Lab order
  • ORU^R01Result
  • OUL^R22Unsolicited lab
  • ADT^A01Admit
  • ADT^A04Register
  • ADT^A08Update info
  • MDM^T02Document
  • SIU^S12Schedule
  • VXU^V04Immunization
  • DFT^P03Charge
  • BAR^P01Billing

FHIR R4 / R5 diagnostic resources

  • DiagnosticReport
  • Observation
  • Specimen
  • ServiceRequest
  • MolecularSequence
  • Patient
  • Encounter
  • Practitioner
  • Coverage
  • DocumentReference
  • Condition
  • MedicationRequest

USCDI v3 + LOINC + SNOMED CT. Maps target the US Core profiles for the USCDI v3 data classes your consumers require. LOINC codes are preserved on every OBX segment, and SNOMED CT, RxNorm, ICD-10-CM and UCUM normalization runs in the same maps. IHE LAB-TF profiles (LCC, LBL, LAW) and PIX/PDQ/XDS are built for your engagement on the same runtime.

Instrument & LIS coverage

Six disciplines. Every analyzer on the floor. One runtime.

The analyzers and LIS platforms that live in production labs. Their results reach iQBus as HL7 v2.x through your LIS, over SFTP, file share or API. Instrument-level transports and LIS-specific connections are built for your engagement, typically in days.

5 analyzers

Chemistry

Roche cobas pro · Siemens Atellica · +3

5 analyzers

Hematology

Sysmex XN · Beckman DxH 900 · +3

5 analyzers

Immunoassay

Abbott Architect · Roche cobas e · +3

5 analyzers

Microbiology

bioMérieux VITEK 2 · Cepheid GeneXpert · +3

5 platforms

Molecular / NGS

Illumina NovaSeq · Hologic Panther · +3

5 analyzers

Blood bank

Ortho Vision Max · Werfen ACL · +3

Formats & transports In use today

HL7 v2.xFHIR R4 / R5 (JSON)XSLT 3.0 mapsSFTPFile shareREST APIAzure BlobAzure Service Bus

LIS platforms we connect: Cerner PathNet, Epic Beaker, Sunquest, Orchard and more.

On request Built for your engagement

MLLPASTM E1394POCT1-A2SMART on FHIRIHE LAB-TF

New adapters are built for your engagement, typically in days. Our adapter library grows every week.

View the full analyzer & LIS listHide the full list
01 · Chemistry

Routine & specialty chemistry

  • Roche cobas pro / 8000
  • Abbott Alinity c
  • Siemens Atellica CH
  • Beckman AU5800
  • Ortho Vitros XT
02 · Hematology

CBC, coag, flow

  • Sysmex XN-Series
  • Beckman DxH 900
  • Abbott Alinity h
  • Siemens ADVIA
  • BD FACSLyric
03 · Immunoassay

Endocrine, tumor, cardiac

  • Abbott Architect
  • Roche cobas e
  • Siemens Atellica IM
  • DiaSorin LIAISON
  • Ortho Vitros ECi
04 · Microbiology

ID, AST, MALDI-TOF

  • bioMérieux VITEK 2
  • BD Phoenix M50
  • Bruker MALDI Biotyper
  • BD BACTEC FX
  • Cepheid GeneXpert
05 · Molecular · NGS

Sequencing & PCR

  • Illumina NovaSeq / NextSeq
  • Thermo Ion GeneStudio
  • Roche cobas 6800
  • Hologic Panther Fusion
  • QIAGEN QIAstat-Dx
06 · Blood bank · Transfusion

Type, screen, cross-match

  • Ortho Vision Max
  • Immucor NEO Iris
  • Bio-Rad IH-1000
  • Grifols Erytra
  • Werfen ACL TOP

LIS platforms in lab estates. Cerner Millennium PathNet · Epic Beaker · Sunquest · SCC SoftLab · Orchard Harvest · LigoLab · Apollo LIMS · Aspyra CyberLAB · Meditech LIS · Halfpenny Technologies. Custom LIS via HL7 v2.x over REST or scheduled file drop; MLLP is built for your engagement.

Ordering EHR coverage

Every EHR sending you orders. Every EHR consuming your results.

The EHRs upstream of your lab, whether they send ORM/OML orders or receive FHIR DiagnosticReport resources. iQBus reaches them through the interfaces your estate already uses; vendor-specific connections are built for your engagement.

Epic

MyChart · Bridges · Care Everywhere

HL7 v2.5.1 · FHIR R4

Interfaces it exposes

  • HL7 v2.5.1 interfaces
  • FHIR R4 endpoints via Bridges
  • Care Everywhere XCA/XDS document share
  • Carequality & eHealth Exchange
  • OAuth 2.0 (SMART on FHIR)

Oracle Cerner

Millennium · HealtheIntent · CareAware

HL7 v2.5 · FHIR R4 · CCDA

Interfaces it exposes

  • HL7 v2.5 interfaces
  • FHIR R4 with US Core profiles
  • CCDA continuity-of-care documents
  • HealtheIntent population queries
  • OAuth 2.0 client-credentials

Allscripts / Veradigm

Sunrise · TouchWorks · Practice Fusion

HL7 v2.4 / 2.5 · FHIR R4

Interfaces it exposes

  • HL7 v2.4 and v2.5 interfaces
  • FHIR R4 read and write-back
  • Allscripts Open API (Unity)
  • Sunrise Clinical Manager
  • Practice Fusion FHIR endpoints

Athena · NextGen · eClinicalWorks

Athenahealth · NG Enterprise · eCW

HL7 v2 · FHIR R4 · native APIs

Interfaces it exposes

  • athenaOne FHIR R4 + native API
  • NextGen Enterprise HL7 v2 + FHIR
  • eClinicalWorks HL7 v2 + Open Interfaces
  • Greenway Intergy & PrimeSuite
  • OAuth 2.0 SMART on FHIR

Long tail we see in lab estates: Meditech Expanse, Allscripts dbMotion, Sunrise CIS, Greenway PrimeSuite, McKesson Paragon, NextGen Healthcare, Practice Fusion, CPSI Evident, Harris MEDITAB, AdvancedMD, DrChrono, Kareo, Amazing Charts. The EHRs above represent the highest-volume customer estates, and our adapter library grows every week.

Every kind of lab

Reference, clinical and specialty labs. One integration backbone.

From routine chemistry to molecular sequencing, the same HL7 → FHIR runtime fits the estate.

Reference laboratory
Reference labs

High-volume result routing

Multi-instrument estates, ORU/OML/OUL into FHIR R4 DiagnosticReports.

Clinical hospital laboratory
Clinical / hospital

LIS ↔ EHR, both ways

Epic Beaker and Oracle Cerner orders in, FHIR results back.

Molecular genomics sequencing laboratory
Specialty / molecular

FHIR R5 MolecularSequence

NGS and clinical genomics endpoints for the partner network.

Lab compliance posture

The posture your compliance officer, CAP inspector and CISO already trust.

iQBus runs entirely inside your own Azure subscription, so PHI, PII and ePHI stay in your tenant. iQBus supports SOC 2 and HIPAA. Controls include end-to-end message tracking, encryption in transit and at rest, Key Vault-held secrets, Entra ID-secured operator access, configurable retention, and one-click resume for failed runs during CAP / CLIA inspection windows.

Tenant-scopedYour Azure subscription

iQBus runs in the customer’s Azure subscription. Message data, tracking history and configuration stay in your tenant, with no multi-tenant control plane handling your PHI.

SOC 2 & HIPAAiQBus supports both

iQBus supports SOC 2 and HIPAA. It runs on your Azure services and inherits your tenant’s controls, so your compliance boundary does not move.

EncryptionIn transit and at rest

Encryption in transit for every external connection and at rest on Azure’s own services, with secrets held in your Key Vault.

Entra IDIdentity & least privilege

Operators sign in with Microsoft Entra ID, so the conditional-access policies you already enforce in your tenant apply to the integration console.

CAP / CLIA inspectionsTracked message history

Every inbound and outbound message tracked under your retention policy. Failed runs suspend with their context and resume in one click, the trail your CAP inspector asks for without ad-hoc scripts.

USCDI v3 · IHEUS Core + LOINC

Maps target US Core profiles for the USCDI v3 data classes your consumers require, with LOINC codes preserved across the transformation. IHE LAB-TF workflows (LCC, LBL, LAW) and PIX/PDQ/XDS are built for your engagement.

In production

Built for the realities of lab integration.

Every result, translated and tracked

HL7 v2.x orders and ORU^R01 results become FHIR R4 / R5 resources, with every message tracked end to end across your LIS, analyzers and ordering EHRs.

HL7 v2.x · ORU / OML / OUL · FHIR R4 / R5

PHI stays in your tenant

iQBus runs entirely inside your own Azure tenant, on your identity and keys, so patient data and integration logic stay within your compliance boundary.

Your Azure tenant · Tracked end to end · No PHI egress to us
Free lab integration assessment

We’ll map your analyzers, your LIS and your downstream EHRs. Written report in one week.

An iQBus senior healthcare-integration architect inventories your analyzer interfaces, your LIS topology and your downstream HL7 / FHIR consumers, and returns a written readiness assessment: gaps in ASTM / HL7 coverage, a FHIR R4 / R5 resource mapping plan for DiagnosticReport, PHI / ePHI handling exposure, and a wave plan for cutover.

  • Written assessment within 5 business days of intake
  • Reviewed by a senior healthcare-integration architect, not a generalist
  • No cost. NDA on file before any interface inventory is reviewed.
  • A format your compliance officer can share internally without redaction
We reply within one business day to confirm intake.
Not ready for the assessment?

Try the Starter Plan in your Azure tenant. No license fee, ever.

Install the Starter Plan from Azure Marketplace and route a sample analyzer feed into FHIR R4 in your own subscription. PHI stays in your tenant, and you pay only your own Azure.